Search results

  1. Jimrahbe

    Converting pool with copper main drain to salt water?

    You are a much better man than me... :mrgreen: I have never been able to get it to reliably work on my two rent house pools... Thanks, Jim R.
  2. Jimrahbe

    New EVO 614i Robot Pool Cleaner Review

    22, Since you live in AZ, I would recommend the finer filter... Most people don't have pounds of dirt in their pools, like many in AZ do. Thanks, Jim R.
  3. Jimrahbe

    Intelliflo 2 VST (2016/2017 model) Leak and Corrosion

    Ben, You obviously know the corrosion came from the leaking shaft seal... :cry: A new pump should be in the $1,600 range... https://www.polytecpools.com/Pentair-IntelliFlo3-VSF-30HP_p_9748.html The control heads do not fail all that often, but... They are the number one item to fail on...
  4. Jimrahbe

    Converting pool with copper main drain to salt water?

    W, Then most likely you don't have an operating main drain right now... Do you have floating diverter valve under your skimmer basket... ?? If you are like most pool owners, you do not.. This mean that your main drain is not operational... I am surprised that your pool contractor, did...
  5. Jimrahbe

    Intelleflo vsf RW-485 cable connector

    Forest, It is a screw-on connector.. But you should just put the automation into the Service mode and then you can use the pump's display. Also something to check... When in AUTO the pump's display should show "Display Not Active".. If it does not show that, then the automation is not...
  6. Jimrahbe

    Converting pool with copper main drain to salt water?

    W, I'd plug it if it ever fails.. Is your main drain run back to the equipment pad, or does it go into the bottom of your skimmer?? Thanks, Jim R.
  7. Jimrahbe

    Adding SWG - Now Facing Pump Issue

    17, That is a load of Bull Feathers... Who told you that? The pump and the cell can be on the same breaker.. But they suggest that nothing else be connected to that same breaker. Thanks, Jim R.
  8. Jimrahbe

    Difference between online retailer and dealer pump purchase

    77, I believe that to get the full warranty you still have to get a "professional" to install it.. Thanks, Jim R.
  9. Jimrahbe

    New EVO 614i Robot Pool Cleaner Review

    John, I assume that was just a test, to see what the EVO could pick up.. :scratch: Or do you plan on manually vacuuming every time? Thanks, Jim R.
  10. Jimrahbe

    Intellichlor40 stuck on 100%, no automation

    7, I think your cell is bad, but I'd want to check that nothing is connected to the com port inside the Power Center.. Show us a pics of the card inside the power center. Sorry, Jim R.
  11. Jimrahbe

    Difference between online retailer and dealer pump purchase

    T, You are correct. I recommend these guys.. https://www.polytecpools.com/IntelliFlo3-VSF_c_763.html Are you getting a display or relay card??? Thanks, Jim R.
  12. Jimrahbe

    IntelliCenter Programming Confusion

    Adam, The first issue is that you can't open the deck jets valve "half" way.. It will be full on or full off.. You can manually adjust the valve so that it stops at half way, but then it will always stop at half way. Second possible issue.. Have you used the deck jets yet? Do you know that...
  13. Jimrahbe

    OK to hook Pentair SolarTouch controller to Intermatic timer?

    David, Thanks for the whole story... I doubt that turning things on and off each day using the timer will hurt anything. Thanks, Jim R.
  14. Jimrahbe

    Spa draining when equipment is off

    Mike, If you open the check valve, the pump can not be running... If you open it when the spa water is low, I would expect some water to flow out, but it really depends on your plumbing.. Just take it out, clean it up and stick it back in. Make sure it goes back in the same direction it came...
  15. Jimrahbe

    OK to hook Pentair SolarTouch controller to Intermatic timer?

    David, I am puzzled?? VS pumps have their own internal timers and should get constant AC power. I thought the SolarTouch also had an internal timer and could control the pump?? Please tell us what specific pump you have, and why you want to run using an external timer box? Maybe I just...
  16. Jimrahbe

    Spa draining when equipment is off

    Mike, I would open the check valve and clean it out and reinstall the check valve and see if that fixed it. If not, I'd buy an OEM replacement for the flapper assembly.. Most spas drain down to just below the jets, but.. it really depends on the water level in the spa.. it will only drain...
  17. Jimrahbe

    Spa draining when equipment is off

    Mike, If the spa drains down to just below the jets, then about 85% of the time it is a dirty or bad check valve on the spa jet line.. This has nothing to do with the check valve by the heater.. If the spa drains down well below the jets then that is normally some kind of issue with the spa...
  18. Jimrahbe

    Help Needed - SPA Draining Into Pool When Spa Is Turned On

    Alex, Glad it was an easy fix and that there was nothing broken.. Jim R.
  19. Jimrahbe

    Drain brown pool water or chemicals?

    I would drain it... Thanks, Jim R.
  20. Jimrahbe

    Help Needed - SPA Draining Into Pool When Spa Is Turned On

    Alex, The valve at very top of the pile.. Right after your IC40 salt cell. Thanks, Jim R.
  21. Jimrahbe

    Help Needed - SPA Draining Into Pool When Spa Is Turned On

    Alex, Your Intake valve is moving like it should.. The problem is not that the spa is draining, it is that there is no water coming into the spa... This is because the Return valve (Right after your SWCG) is not moving.. It is in the same position in the Pool mode and in the Spa mode. It...
  22. Jimrahbe

    Question on upgrading Compool cp3810 to EasyTouch and ScreenLogic as it pertains to pumps

    Doc, Yes.. If you plug something into the spa relay port, it will turn on the relay anytime you are in the spa mode. There may be other ways to do this, but I believe this will be the simplest one. Thanks, Jim R.
  23. Jimrahbe

    Help Needed - SPA Draining Into Pool When Spa Is Turned On

    Alex, I doubt that resetting the breakers will do anything, but it can't hurt. Step one would be to see where the valve is in the Pool mode and then in the Spa mode. Let us know what you find. Thanks, Jim R.
  24. Jimrahbe

    Help Needed - SPA Draining Into Pool When Spa Is Turned On

    Alex, You list valve B as Pool and Spa.. You need to look at valve B.. When in the Pool mode, the "off" tab needs to point to the pipe going to the spa drain. When in the Spa mode, the "off" tab needs to point to the pipe going to the Pool skimmer/main drain. The only way water can get...
  25. Jimrahbe

    Question on upgrading Compool cp3810 to EasyTouch and ScreenLogic as it pertains to pumps

    Doc, Sorry I lost track of where we are.. :cry: I know that this system is for controlling your spa, but since your spa has its own equipment, it will need to run x hours a day to keep the spa sanitized and clean.. Does not need the heater.. This means that you should schedule Pool for X...
  26. Jimrahbe

    Help Needed - SPA Draining Into Pool When Spa Is Turned On

    Alex, It sounds like your Intake valve (the one in front of the pump) is sucking water from the spa when in the pool mode.. Either the Intake actuator is bad or the little toggle switch is in the wrong position.. Watch the Intake valve when you select the pool mode, and then the spa mode, and...
  27. Jimrahbe

    Better to run VSP 24/7 or install a timer?

    End, I do not see a heater in your signature.. Without a heater, you should not have to run very fast to close the flow switch. If you don't already have your new salt cell, it would make sense to install it and see what it takes to turn it on.. Then you can decide if you want the cell to...
  28. Jimrahbe

    Better to run VSP 24/7 or install a timer?

    End, Does the air under the pump lid keep getting bigger and bigger?? If so, you have a suction side air leak, you should fix. Have air under the pump lid at low RPMs is normal, but it should not continually increase. Thanks, Jim R.
  29. Jimrahbe

    Better to run VSP 24/7 or install a timer?

    End, I am not sure I fully understand... :scratch: In my mind it does not make sense for the pump to be running and the SWCG not making chlorine... My SWCG's flow switch closed about 1100 RPM, so I run at 1200 RPM, most the time. Running 24/7 costs me less than $20 bucks a month. I...
  30. Jimrahbe

    Question on upgrading Compool cp3810 to EasyTouch and ScreenLogic as it pertains to pumps

    Doc, What does your little display show?? AUTO Pool or Spa or blank???? Temp Date. When you set the system up as a single body system, did you set it up as a "Spa"? If so, then you will have to move the Pump/Filter relay connection from the Pool port to the Spa port.. otherwise the...