polaris 360

  1. J

    Polaris PB4-60 cycling

    First post, relatively new pool owner, but im having an issue with my polaris pb4-60 cycling when turned on. I have a 1.5 hp main pump and when they are both running the polaris turns on for less than 30 seconds then shuts off for the same time and this will continue the whole time its in...
  2. R

    Nut coming off of swivel connector

    Hi All - I have a Polaris 360 and no matter how many times I change the nut and reconnect, the hose comes off (while on higher speeds) leaving the nut on the end of the hose having slipped off of the connector. Any suggestions or solutions? Thanks in advance!
  3. L

    CircuPool's SWG - 10 psi warning label

    I'm starting a new thread on this topic so as to get up-to-date information from @circupool or others on the overpressure warning label that is attached to (some?) CircuPool SWG cells. I've just ordered an RJ-60 Plus that will be installed on an existing pool that has a Polaris 360...
  4. F

    Vacuum 101

    Hi! I’m new here. I tried searching but didn’t see an appropriate answer within the first few pages of results, though I imagine this has been answered countless times. I bought a house two years ago and a Polaris 360 pressure-side cleaner came with the pool. When it works, it works. However...
  5. O

    Upgraded Filter - Polaris 360 not working

    We just upgraded from a cartridge filter to a DE filter. The repair technician took it upon himself to remove the Jandy Energy filter from the line and changed up the plumbing, saying the energy filter wasn't necessary. We have a Polaris 360 cleaner that hasn't worked properly since the...