    Blue Surf Pebble Sheen Question

    This is at about 4 years old. I think it has lightened up a bunch. But maybe that's from running the chlorine levels a little higher than I should have. Not sure.
  2. IMG_8182.jpeg

    IMG_8182.jpeg

  3. J

    Heater bolts corroding

    Here are my full tests from today. Still trying to understand if chemistry caused my problem. I will update again when I pull the manifold.
  4. IMG_7703.jpeg

    IMG_7703.jpeg

  5. IMG_7701.jpeg

    IMG_7701.jpeg

  6. J

    How to install auto bypass for heater with IntelliCenter.

    That’s what I don’t get. My ph tends to run high from the spa waterfall and the swg. Every time I test it’s solid purple and then 1 acid demand drop gets it to 7.4 color so I add 4 -6 cups of acid. Usually about once a week for a 20k gallon pool. I am really struggling to understand the issue.
  7. J

    How to install auto bypass for heater with IntelliCenter.

    Thanks for the quick responses. This will be my protect over the next week. Then to decide if I should open up my rusty manifold or just leave it. I found a local heater that someone is selling and I may just swap my unit. I also have to check my TA a few times. I am wondering if running...
  8. J

    How to install auto bypass for heater with IntelliCenter.

    I have a pre 2/2021 master temp so no heater bypass on heater circuit board. I want to connect an auto heater bypass to my IntelliCenter. Does anyone have instructions for how to do that. I have the plumbing diagram so that part is a known. I am looking for the actual port to use on the...
  9. J

    Heater bolts corroding

    Just the metal in the filter. Not really bad but shows rust. I have to pop off the manifold at some point. Probably will install an auto bypass since my intellicenter should handle it.
  10. J

    Heater bolts corroding

    I wonder if adding stabilizer to the skimmer did this. I don’t use a skimmer sock and thought it was ok since it gets to filter first. This was usually once a season in the spring to get cya up. But maybe that caused an issue. I am beyond sad that this happened this quick as I thought I...
  11. J

    Heater bolts corroding

    What type of chemical problems can cause it? My ph never gets really low. It may get a little high in the middle of winter but using the LSI calculations seem to suggest when water is cold that doesn't matter as much. I have been maintaining the pool and use all the tfp testing kits and try...
  12. J

    Heater bolts corroding

    Do you have the specs on the bolts? Thanks for all your help!
  13. J

    Heater bolts corroding

    I didn't see any water coming out of the bottom hole. I tried one further up (that still could be turned) and didn't see water there either. I was running in pool mode which is a slower RPM (2200) vs spa mode. Maybe my spa mode is turned up too high? I did have it set near max (3100) trying...
  14. J

    Heater bolts corroding

    I took one of the bolts out and no water came out. Pump was off. Should that be done under pressure?
  15. J

    Heater bolts corroding

    Any risk to waiting for it to fail by leaking without the bolts removed? Or should I be proactive in fixing it? I would still like to understand what is happening that caused it. I try to keep ph in check it always goes to 8 and then I dose with acid to about 7.4. My chlorine levels have...
  16. J

    Heater bolts corroding

    If water comes out does that mean the exchanger has failed?
  17. J

    Heater bolts corroding

    There isn’t a check valve between ic40 and the heater. Could that be an issue? It really looks like corrosion from chlorine to me. But I don’t know how it could be outside the manifold. The bolts are toast. I am going to have to drill them out likely. So not trying to remove unless I...
  18. J

    Heater bolts corroding

    I think they just put a label up there. The real back wash line is on the bottom of the slide.
  19. IMG_7599.jpeg

    IMG_7599.jpeg

  20. J

    Heater bolts corroding

    How long does that normally take? A few years ago in the Texas freeze my heater was accidentally on for a few days. I was debugging a HLS error and saw my bolts are all rusted on the manifold. Trying to figure out what happened.
  21. J

    Heater bolts corroding

    It’s only 4 years old.
  22. J

    Heater bolts corroding

    What causes this kinda corrosion on these outside bolts of Pentair heater manifold case?
  23. IMG_7598.jpeg

    IMG_7598.jpeg

  24. J

    MasterTemp 400 Control Board and Intellicenter

    If the board is upgraded can the new board be hooked up to intellicenter via the rs485 connections?
  25. J

    I may have to give up my beloved SWG :(

    What did you end up doing? I know it’s an old thread but in a similar position with my pool. Hard to find people that have the prosoco OH100 consolidator. Will keep looking. Have some stain proof 40sk that I am going to try after the consolidator or maybe just by itself. Have used...
  26. J

    Natural Rock Damage with SWCG

    Here are some pics from over 2 years later... any recommendations for what I should replace these rock with? I am thinking about some rock look porcelain tiles but I am sure that might be a challenge. I have no idea if this is from the salt levels, just plain erosion or just really bad...
  27. 20240527_010008797_iOS.jpg

    20240527_010008797_iOS.jpg

  28. 20240527_005723061_iOS.jpg

    20240527_005723061_iOS.jpg

  29. J

    Polaris Quattro Sport (side pressure cleaner) - drive shaft repair and fix!

    How long have you had the cleaner? What did you have before? I have a Pentair racer now and thinking of going the Polaris route... either the p280 which seems to be recommended a bunch. But these seem like they would do a great job.