Calibrating salinity level

S. Reiss

Member
Nov 23, 2024
8
North Texas
I recently replaced the back board on my Jandy system and after firing it up I'm getting a "145' error, high salinity - 25400, which I knew had to be incorrect as I just had the water tested the previous day. I ran another test, which showed 30.0, and this tells me I need to recalibrate the salinity system.

I followed the necessary steps - press and hold the salinity button until you hear 3 beeps, press the Temp button, then adjust the salinity level. After doing this, though, the display reads "H.H gpl" and won't allow me to make any adjustments. What can I do to clear this? Will I need to clear the memory through iAqualink and reset everything?

Please help.
 

Disconnect the flow salinity temp sensor from the front board.

Press and hold the test buttons marked salinity and R-temp.

While still pressing the test buttons press the ‘Salinity’ key (‘C’) on the front cover of the unit.

The LCD should read 2.8 gpl*.

While still holding the two front board test buttons press the ‘Pool Temperature’ key (‘D’).

It should read 75° F or 24° C.

Next, press and hold the board ‘H-Temp’ test button, and at the same time press the ‘Salinity’ key (‘C’) together with the ‘Chlorine Production Rate’ arrow down key (‘A’) on the front cover of the unit.

The LCD should read 91° F or 33° C .

If the readings are correct then the front board is O.K. and the problem is with the flow sensor.

On the other hand if the readings are different then it indicates that there is a problem with the front board.

When the testing and repair is complete reconnect the flow sensor and reset the internal computer (do this by restarting the unit).

*Note: If the the salinity reading has been recalibrated this reading maybe different.

Before condemning the board check salinity setting.
1732460264295.png
 

Attachments

  • jandy-aqua-pure-error-codes.pdf
    2.9 MB · Views: 0
  • Like
Reactions: S. Reiss
Here's the update....

Part 1:
Press and hold the test buttons marked salinity and R-temp.
While still pressing the test buttons press the ‘Salinity’ key (‘C’) on the front cover of the unit.
The LCD should read 2.8 gpl*.

Result: The display flashed 'H.H' then returned to 00% production

Part 2:
While still holding the two front board test buttons press the ‘Pool Temperature’ key (‘D’).
It should read 75° F or 24° C.

Result: The display showed 74 F

Part 3:
Next, press and hold the board ‘H-Temp’ test button, and at the same time press the ‘Salinity’ key (‘C’) together with the ‘Chlorine Production Rate’ arrow down key (‘A’) on the front cover of the unit.
The LCD should read 91° F or 33° C .

Result: The display showed 90 F


Since the 1st part of the results flashed 'H.H', should I assume this indicates a bad PIB? I hope not as this would replacement #3.
 

1732464480330.png
Jandy AquaPure Service Codes

Code # Possible Cause Solution
120 Low current in forward direction to cell Clean cell if necessary and check DC cord
121 Low current in reverse direction to cell Clean cell if necessary and check DC cord
123 Extremely low current to cell Clean cell if necessary and check DC cord
124 Higher than normal current to cell Contact a pool professional
125 Cell needs to be cleaned Clean cell if necessary
126 Low current in forward direction and VAC input voltage below 100-200 VAC Contact a pool professional
127 Low current in reverse direction and VAC input voltage below 100-200 VAC Contact a pool professional
144 Low Salinity (below 2.0 gpl) Add salt to pool to achieve 3.0 gpl
145 High Salinity (above 4.0 gpl) Backwash filter if a DE filter is installed. Partially drain pool and dilute with fresh water until salinity returns to 3.0 to 3.5 gpl
170 Possible front board service condition or unit not correctly wired to 120 VAC Contact a pool professional
171 Possible backboard service condition Contact a pool professional
172 Flow sensor service condition or flow sensor is unplugged Contact a pool professional
173 Low VAC input voltage and on board power supply is not regulated or unit not correctly wired Unit wired to improper AC voltage. Contact a pool professional
174 Pool temperature is too high for operation of AquaPure Flow/Salinity sensor indicated water temperature at sensor above 108 degrees F. Reduce water temperature
175 Flow sensor air lock condition or very low salinity Verify proper flow/temperature/salinity sensor installation. Check salinity with Myron “L” meter calibrated for NaCl or test strips. Add salt as necessary

Level 2 Service Codes

Code # Possible Cause Solution
180 Heated sensor element not heating. (Generates 172 code) Contact a pool professional
181 Flow sensor temperature sensor failure. (Generates 172 code – flow sensor service) Contact a pool professional
182 Salinity Sensor sees less than 0.2 gpl of salt, no salt in pool or sensor air locked. (Generates 175 code – flow sensor air lock) Contact a pool professional
183, 184, 185, 186 Flow salinity sensor temperature probe error codes. (They will all generate 172 codes which indicate flow sensor service is required) Contact a pool professional
187 Front board power supply either too low or too high. (Generates 173 – Low input voltage code if Level 2 code 188 is present) (Generates 170 code if 188 is not present) Contact a pool professional
188 VAC input voltage is too low. (Generates 173 code if Level II code 187 is present) Contact a pool professional
189 Relay not conducting in the forward direction. (Generates 171 code – Backboard service) Contact a pool professional
190 Relay not conducting in the reverse direction. (Generates 171code – Backboard service) Contact a pool professional
191 High cell current (at upper limit of A/D converter) and cell voltage below 19V. (Generates 170 code front board service) Contact a pool professional
192 High cell current and cell voltage below 19V. (generates 171 code – Backboard service) Contact a pool professional
193 Measured significant cell current when SCRs were turned off. (Generates 170 code – front board service) Contact a pool professional
194 Cell Current is 85% lower than desired and cell voltage above 19V (Generates 125 code – Cell dirty or needs replacement) Contact a pool professional
195 Salinity invalid due to out of range measurements caused by front board error (Generates 170 code – front board service) Contact a pool professional
 
Last edited:

Enjoying this content?

Support TFP with a donation.

Give Support
Check the two attachments. The board with the red connector is the original board from 2008 when the pool was first installed. The board with the black connector is replacement board #1. I replaced it because it wouldn't detect the Aquapure. Replacement #2 that is currently connected and running found the Aquapure, but only if I attached the jumper that I have circled. Replacement #2 is the 1 sending the H.H error.

Just for testing, I reinstalled replacement #1 and didn't get the H.H error, but it still wouldn't connect to the Aquapure even with the jumper in place.

I'm leaning towards getting another board since #1 didn't think the salt level was high and didn't give the H.H error like board #2 did.

The H.H code indicates very high salinity, as noted in the first post, and the only way to correct that is dilution. It's an easy fix, but I know the salinity is not high, it is 3.0 and was tested twice in the past 2 days by myself and a tech at Leslie's pools.
 

Attachments

  • 20241124_101424.jpg
    20241124_101424.jpg
    666.3 KB · Views: 2
  • 20241124_100841.jpg
    20241124_100841.jpg
    892.4 KB · Views: 2
Last edited:
Jandy R0984100 Power Interface PCB Large Backboard with Screws for AquaPure. Replaces R0467600

6 R0467600 Power Interface Board Assembly Screws, Power Interface





Jandy Power Interface PCB, Zodiac PureLink, R-Kit, Next Gen - R0984100​


Jandy R0984100 Power Interface PCB Large Backboard with Screws for AquaPure and PureLink

Used on units manufactured after 12/2007.




 

Attachments

  • h0573500.pdf
    2.1 MB · Views: 0
  • h0296900.pdf
    1.6 MB · Views: 0
  • h0325600.pdf
    3.8 MB · Views: 0