I recently scheduled my filter pump however it’s not doing what I’ve scheduled it to do.

The 11 am to 4 pm runs fine on high
The 4:01 pm to the 10 pm runs fine in low speed
The 5pm to 10:59 is running on high not low as I’ve scheduled.

Any ideas what I’ve done wrong in scheduling see attached screen shot

Thanks in advance for and help.
Rod
 

Attachments

  • IMG_7362.png
    IMG_7362.png
    109.7 KB · Views: 15
Is it just a 2 speed pump?

Why do you have the pool low twice with overlapping schedules.

I suggest you turn the Filter pump on the entire time you want it on then change speed as needed.
 
I agree with @PoolGate, Filter-pump should be scheduled for the whole duration of the runtime, and the low speed function of the pump should be connected to the filter pump relay.

Then it always runs low speed when the filter / pump is on. Then schedule your Pool High speed (or the Aux associated with high speed) for the subset of time you want it to run.
 
I agree with @PoolGate, Filter-pump should be scheduled for the whole duration of the runtime, and the low speed function of the pump should be connected to the filter pump relay.

Then it always runs low speed when the filter / pump is on. Then schedule your Pool High speed (or the Aux associated with high speed) for the subset of time you want it to run.