Hi all - see attached photo of my home grown solar heater. 3 arrays, flow is in the bottom, out the top of the panels. Works pretty well - measured a 5-8° temp increase depending on conditions.
Have a problem with the top row getting an air lock on the two highlighted panels. Added a VRV this season but the problem persists. I manually disconnect the panels and purge air out of them and they work fine for a while then flow stops through them again.
Pressure at the filter is consistently about 15psi. Pump is a 1 HP Hayward superpump.
Any ideas to fix
Have a problem with the top row getting an air lock on the two highlighted panels. Added a VRV this season but the problem persists. I manually disconnect the panels and purge air out of them and they work fine for a while then flow stops through them again.
Pressure at the filter is consistently about 15psi. Pump is a 1 HP Hayward superpump.
Any ideas to fix