Replacing Bulkhead Inlet

cookbe911

Member
Mar 11, 2024
5
Hondo, Texas
Pool Size
10000
Surface
Plaster
Chlorine
Salt Water Generator
SWG Type
Jandy Aquapure 1400
Hello, I have a leak on the inlet of my Jandy 460 Filter housing. I first tried tightening the end cap and it cracked which is one problem. In the process of trying to remove the bulkhead I realized I couldn’t remove the broken end cap because of the lip on the other end of the bulkhead. I thought it was screwed on but now it looks like it’s glued on. How am I supposed to replace the bulkhead in this case? Is there an easier way? I have attached a pic.

Thanks in advance!

IMG_6676.jpeg
 
Last edited by a moderator:
It appears the hand nut has broken. Search 2" union split nut repair.
It replaces the hand nut with a two piece that connects together around the fitting that goes into the filter.
Thanks, I will try that. I will let you know how it goes!
 
Last edited:
Hello, I have a leak on the inlet of my Jandy 460 Filter housing. I first tried tightening the end cap and it cracked which is one problem. In the process of trying to remove the bulkhead I realized I couldn’t remove the broken end cap because of the lip on the other end of the bulkhead. I thought it was screwed on but now it looks like it’s glued on. How am I supposed to replace the bulkhead in this case? Is there an easier way? I have attached a pic.

Thanks in advance!

View attachment 557706
Easiest is to cut the tailpiece off flush with the fitting (labeled Lasco). Glue in a 2" pipe extender.
1710453045569.png

Install a new assembly (R0522900).
1710452971562.png
The split-nut that fits a Jandy bulkhead/half-union is hard to find.
 
  • Like
Reactions: cookbe911