Recent content by sansuncal

  1. S

    Check valve at pump suction

    Haha .. reminds me of physics lectures. May be it is not bad as it seems like. Thanks all!
  2. S

    Check valve at pump suction

    Yes spa is on a separate shared 5 hp pump with pool so not a worry there. I am just angry at the plumber who didn’t care to ask me or PB who plumbed 3” suction line for this dedicated pump for rain curtain to maintain needed flow.
  3. IMG_3284.png

    IMG_3284.png

  4. S

    Check valve at pump suction

    Yikes. That is my worry too, as pump needs to push at least 120 gpm for rain curtain and I wanted to run it at lower to mid speeds. That was the whole reason to plump 3” suction line for this water feature pump. Let me talk to PB tomorrow.
  5. S

    Check valve at pump suction

    My PB’s plumber relocated 3HP Pentair VS pump and I later noticed that he just cut old 2’ pipe to the edge and left that inside check valve and then spigot new 2.5” pipe in n the check valve. Pump has 3” suction line before this check valve. It looks like pipe size is going from 3” suction line...
  6. S

    Intellicenter upgrade - screen not powering up

    Yes that explains why daughter card has power and probably all actuators as well. I just PMed you to see what are ways to troubleshoot. Thanks
  7. S

    Intellicenter upgrade - screen not powering up

    Yes looks like main board is dead. it was an open box item from ebay so no avenue for warranty. :(
  8. S

    Intellicenter upgrade - screen not powering up

    I reconnected the transformer again to 120 V ie black to L and purple to N and checked AC V on output. Reds read 26.7 v and oranges read 20v or so. So it's sending power to both relays and system boards. Whats isnt making sense is why only the auxs on expansion board are getting power and there...
  9. S

    Intellicenter upgrade - screen not powering up

    Pump's 485 connection is good and no shorts Small little pins for wifi has 24 v Nothing happening when expansion board is not connected So looks like system only has 24 v supply that is powering up valves etc but not sure about 18 v that IC needs. Is there anyway to check the voltage safely...
  10. S

    Intellicenter upgrade - screen not powering up

    Thank you all. Let me follow these and report back tomorrow
  11. S

    Intellicenter upgrade - screen not powering up

    I just upgraded from ET-8 to IC i10PS and connected everything as per pentair manual but its not booting up. Valves and relays get power but screen and lan jack are totally off. When powered up, I see lights on daughter card blink then large clicking not sure relay or CB and nothing happens. Its...
  12. S

    We Have a Winner! TFP Pool of the Month (November 2023); Theme - Lighting

    Thank you all for your kind vote and 👍 support. TFP is the best place for pool owners to make their pool efficient and truly enjoyable. We designed this pool and our backyard + lighting ourselves 😀. It was a daunting build due to elaborate process steps required for glass tile installation. We...
  13. S

    We Have a Winner! TFP Pool of the Month (November 2023); Theme - Lighting

    Here is our glass tiles pool with lighting and everyone's wow backlit swim up bar and fav color changing rain curtain! Looks Amazing right :) Thanks 🙏
  14. S

    Pool pump plumbing

    Thank you so much! I have 2 water features, 1 spa spill over and 21k gallons pool and old 3 HP intelliflo with 130 gpm was not enough for all to flow properly and it was too noisy at top rpm. So I hope it will be more efficient and less noisy pump.
  15. S

    Pool pump plumbing

    Yeah thats the route I might take. However this manual says you can add this card and add more pumps etc via 485 cable. Also, I noticed that my PB has hooked up 5 HP pump that draws 20-21 A to a 20 A breaker. Is it going to trip the breaker often? I haven't run this pump yet as pool is getting...