    Ortega valve - can I do without?

    Thought I'd post a follow-up for the next guy with an Ortega valve problem. The simple Ortega "rebuild" (https://www.amazon.com/dp/B0118DFGGA?psc=1&ref=ppx_yo2ov_dt_b_product_details + spring) is working just fine. I'd done this a couple times through the years but had thought it time to get...
  2. H

    Ortega valve - can I do without?

    Thanks Jim...now that I think about it, that's logical. And Poolman, those blue handled valves all go to the pool. I haven't been completely idle. The day I read Jim's response I went out and drained the spa (clean out winter leaves), backwashed the DE filter, and inspected the Ortega "guts"...
  3. H

    Ortega valve - can I do without?

    Thanks for the reply. My thought though is to just block the flow so the spa can't drain at all. (It has a separate overflow into the pool that runs daily.) Do I need the check valve just to facilitate manual draining/cleaning of the spa?
  4. H

    Ortega valve - can I do without?

    My pool has an old Ortega valve between spa and pool. First time I put in new parts (more than 15 years ago) I learned it was considered obsolete at the time. Lately my spa drains down to pool level within 30 min or so of recirculation stopping, so it's not working. I figured it was time to...
  5. PXL_20240425_181142767.jpg

    PXL_20240425_181142767.jpg

  6. PXL_20240425_181134581.jpg

    PXL_20240425_181134581.jpg

  7. PXL_20240425_181115015.jpg

    PXL_20240425_181115015.jpg

  8. H

    Insufficient backwash?

    Update for anyone who reads this thread. After a couple weeks of normal use the system flow slowly improved (as judged by suction and waterfall flow) to where it's only a little less than I saw with the new grids. Not sure how to explain this time-dependent improvement but if the initial...
  9. H

    Insufficient backwash?

    Pressure has been definitely weird. Before the new grids it'd sit at 12psi when good and get up to 20 when very dirty. After the new grids it was about 8, but even after the recent monsoon and poor suction it was reading only 6. At the moment after cleaning and with "disappointing" suction...
  10. H

    Insufficient backwash?

    Right...I hate to do that and really want to be sure it's not just insufficient back wash. I will run in it in this "disappointing mode" until I need another full backwash (we got more monsoon coming this year no doubt) and then backwash the heck out of it. Really my initial question is should...
  11. H

    Insufficient backwash?

    Thanks Allen. My setup doesn't have a rinse position just an up/down valve that switches from pool recirculation to sending the water out. I attach a picture. I'm not sure what physically is happening in each of the steps, particularly the rinse.. Obviously backwash is supposed to send water...
  12. pool filter.jpg

    pool filter.jpg

  13. H

    Insufficient backwash?

    It's a Hayward Progrid - don't see the model - about 10yrs old 3.5ft tall, takes 7.5 grids.
  14. H

    Insufficient backwash?

    My main battle with my pool for 20+ years is maintaining enough suction to keep my skimmer skimming and my Hayward crawler crawling. As the DE filter clogs and the back pressure rises this gets harder and harder. Not enough suction to go around. This year installed new DE filter grids and was...
  15. H

    Pentair light not working

    If you measure 12V across the bulb it should light (transformer is delivering enough current to maintain the voltage drop). Either you're not actually measuring the voltage drop across the bulb or the bulb is defective. Try it with a different 12V source.