The Jandy TruClear does not have a flow switch.
The Jandy TruClear uses a gas sensor to shutdown the cell when there is inadequate water flow instead of a flow switch. The gas sensor uses a conductivity sensor through the water that gas accumulation breaks.
Your manual is at
https://cdn.fluidrausa.com/-/media/...3500.pdf?rev=43b499c64cc34871bc86e185d48f8e4d
Section 3.6 says:
the power pack must be interconnected with the pool pump motor power source to ensure that the chlorinator only operates when the pool pump is running. The Jandy TruClear chlorination system with Firmware Revision F or later, can monitorthe state of the Jandy Variable Speed Pump so that the TruClear does not operate if the Jandy Variable Speed Pump is not running.
The Truclear Power Pack should be wired to the LOAD side of the Aqualink filter pump relay.
Show us where the Power Pack is connected to.