Can I use a 1.5amp fuse in the fireman's switch? These 1.25's are so hard to find, and expensive
What do you mean by the flame wire?Another update! I replaced the aftermarket control board with the legit pentair 6 button control board. The heater works and the pool is 85 degrees and ready for our first pool party tomorrow! I can't thank you guys enough, you saved me thousands of dollars.
I still have one question. I bought the newer control board with the six button membrane as advised in a previous post. I thought it would come with the "flame" wire but it did not. Do i need this wire? If so does anybody have the part number? I can't seem to find it anywhere
If you are referring to the flame sense cable, this is the cable that goes between the Fenwal ICM and the heater control board. If you are only replacing the heater board/membrane pad, then this is not needed. You would need to change out the ICM in order to have this connection. See below excerpt from the ICM instructions Pentair 476249I thought it would come with the "flame" wire but it did not.