Search results

  1. Lake Placid

    10 Day Old IC-40 Just Went Dark

    Only reason I asked was because I was mistaken and thought the cell was immediately adjacent to the heater output. Was speculating that may have been a source of a potential leak, but your pictures cleared it up and my concerns are/were unfounded.
  2. Lake Placid

    10 Day Old IC-40 Just Went Dark

    I always assumed it was a CYA legally to ensure the flow switch will fall down and stop production when flow stops….just my theory. I’ve seen a few like that, didn’t like it but snuggled it into the groove and it sealed. Perhaps dumb luck.
  3. Lake Placid

    10 Day Old IC-40 Just Went Dark

    Is the side that’s leaking the side nearest the heater? I see the 180 degree check and assume the heater is just the other side of that?
  4. Lake Placid

    10 Day Old IC-40 Just Went Dark

    Backside as in the video leads me to believe the flange that is welded on the to pvc pipe has developed a leak. O-ring failure woukd present more than likely on the SWG side of the union. Pull the SWG, slip the nut back from the joint as far as you can and inspect the weld between the pipe and...
  5. Lake Placid

    10 Day Old IC-40 Just Went Dark

    +1 it’s commonly referred to as gluing but is solvent welding. If you look inside an open fitting after it’s properly welded you can sometimes see melted pvc from the inside of the fitting that has moved during the fitting process. If it doesn’t leak pretty much immediately after...
  6. Lake Placid

    10 Day Old IC-40 Just Went Dark

    I have also done plenty with only lubing the ring, but have found in cases where the ring doesn’t want to cooperate, lubing the groove helps hold the oring in place and assists in sealing.
  7. Lake Placid

    10 Day Old IC-40 Just Went Dark

    The o-rings that sit in the groove have a tendency to roll out of the groove just enough to cause a leak. Lube the groove liberally and roll the o-ring into it, pressing it into place making sure it’s fully seated. Then lube the outward facing side while pressing it into the groove. It can...
  8. Lake Placid

    Is a pool refill best option in my case?

    Yes and no…the algae festers in the tank that is your filter contaminating everything in there until you remove some of it through backwashing or cart cleaning. A filter won’t stop algae from reproducing in all the water that passes through it.
  9. Lake Placid

    Stumped with Air Bubbles from Return Jets

    Often times a suction side valve leak can be masked because both valves are open. In your first pic only one side is open. It could be your main drain or your skimmer. Currently the right valve is fully open and the other is closed. If you are seeing bubbles in the current state, reverse the...
  10. Lake Placid

    Stumped with Air Bubbles from Return Jets

    What is your valve setup on the suction side of the pump?
  11. Lake Placid

    Am I dealing with POP (Pool Owner Patience) at this point?

    Stay the course. Given the swamp in the first pic you’ve come light years forward. As NewDude stated it’s either at the point or very close to the point where it just takes time to pass all that water through the filter to catch the debris.
  12. Lake Placid

    Pool Company opened pool Questions abut what they added

    Can Pedro Pedro explain which way they moved PH? Up with soda ash? Down with Dry Acid? A little of each just because the sun was out and you can be billed for 5# of something? A useless piece of info as it’s stated. Good job on getting a test kit, you’ll soon have meaningful data to adjust your...
  13. IMG_0644.jpeg

    IMG_0644.jpeg

  14. Lake Placid

    Snapped jet line and now I can't get it out

    You can also try a set of long 90 degree needle nose pliers to grab on to the recessed plate in the fitting to try and spin it out.
  15. Lake Placid

    Calcium Problem (?) and Constant High PH

    We’ve got some members in your neck of the woods that can help with test kit advice. @mgtfp @AUSpool @needsajet We really need to know your calcium hardness levels to give a proper assessment on calcium. Also will need to know your CYA level to understand how low your FC level is with respect...
  16. Lake Placid

    What did you do to your pool today?

    Well the answer is today. Pool has been clear for a while, but I’ve been swamped and just managed to swing over for a full detail of the pool. Stir bar was 40 feet across the pool in the opposite shallow end from where I dropped it. The dolphin running must have moved it a “touch”. Original...
  17. Lake Placid

    Help...Pentair check valve flapper installation question

    Most I have installed open somewhere between 1/3 to just under 1/2 way when under pressure, dependent on the flow rate, and location in the system.
  18. Lake Placid

    Mysterious pipe

    Could be innerduct. Check around your foundation especially near the service entrance for a similar stub out or termination through a wall with the same pipe.
  19. Lake Placid

    0 CYA and 0 FC. Need advise

    Normal operation wouldn't blow media out of the filter, just BW. I've seen it when priming runs about 3400. I don't want to be overly alarmist, but just provide food for thought. You're probably just fine.
  20. Lake Placid

    10 Day Old IC-40 Just Went Dark

    Pools are like BOATS (Bust Out Another Thousand)....but I have yet to hear of a quippy acronym for POOL.
  21. Lake Placid

    0 CYA and 0 FC. Need advise

    A couple of thoughts. You have a VSP. When you backwash does it kick into priming mode and stay there during the backwash cycle? What RPM is it running at during the backwash? I have seen and have other contacts that have seen sand being blown out of the filter during the backwash cycle...
  22. Lake Placid

    10 Day Old IC-40 Just Went Dark

    I just checked the 2024 catalog in the Pentair Partner web portal. It’s still listed in the 2024 catalog as are all the customary replacement parts. It’s now listed as TradeGrade. So it would appear for the time being it’s staying. I may check in with my Pentair rep if I think about it next...
  23. Lake Placid

    Algea problem - Can't get past cloudy water

    Yep it’s likely an SD. You’re just fine…..You scared me referencing the “cartridge”. It’s been a long day……for a DE filter they are called grids and there are multiple grids in a filter with multiple pvc pipes wrapped in a filter fabric that holds the DE. In a cartridge filter the filter it...
  24. Lake Placid

    Algea problem - Can't get past cloudy water

    A StaRite system 3 is a cartridge filter, not a DE filter. You should not be adding DE to it. It will only impede your progress….Do you have a multiport valve? How did you apply the floc, what process did you follow? It may have been floc in your filter that you cleaned not DE. Have you...
  25. Lake Placid

    Thinking of Opening Myself for the First Time…

    Forgot to ask….Where’d you go to high school?…(It’s a St. Louis thing). 😁
  26. Lake Placid

    Thinking of Opening Myself for the First Time…

    For sure. It’s not as difficult as you would think and pics will help a lot to craft the “battle plan”. 🤣
  27. Lake Placid

    Optimal Salt Level for SWCG

    Older cells actually state 3400 as ideal…..I have one on my pad (2017 mfr date) that states such. Not sure when pentair implemented the change, but I’ve seen 3600 on the newer ones and in current documentation.
  28. Lake Placid

    10 Day Old IC-40 Just Went Dark

    Congrats…no doubt you implemented “The Fix” the right way….you know LP blue jumpers and all. 🤣. All kidding aside give us the deets on how you repaired and how easy you found soldering on to the connector.
  29. Lake Placid

    What did you do to your pool today?

    There was a high speed maneuver as I was diving over the coping with my left hand to grab it. I hit it twice, then the slow motion set in as the bar floated towards the bottom. If the HO was watching I’m sure they thought I was crazy as I almost went in the pool. Water was 60 degrees….it...