Recent content by scoliukos

  1. S

    Pentair Intelliflo3 VSF: extremely low flow rate

    The filter is showing 24 PSI. I’ve asked my pool builder to come and manually clean the filter. He failed to add DE at startup, so it’s been running without that since Monday.
  2. S

    Pentair Intelliflo3 VSF: extremely low flow rate

    Flow does not change when the other two valves are opened. We cleaned a few leaves out of the pump basket and that increased the flow by about 5 GPM. And yes, there is no movement in the skimmers.
  3. S

    Pentair Intelliflo3 VSF: extremely low flow rate

    I have a new gunite pool that was plastered and filled last Sunday (4/21). My equipment is as follows: Pentair Intelliflo3 VFS (1.5HP) Pentair FNS plus DE filter (36sqft) Pentair Mastertemp 400 5 returns + 2 skimmers As of today, with the pump running at 100% speed, my flow rate is 13 GPM...
  4. IMG_9003.jpeg

    IMG_9003.jpeg

  5. IMG_8994.png

    IMG_8994.png