Recent content by MMCP

  1. M

    WhisperFlo VS and intelliconnect

    Wanted to report back as I was finally able to reroute the plumbing and have IC40 horizontal now. Went from having to run at 2500 rpm for flow switch on IC40 all the way down to 1100. A big part of the problem was the pool guy had too small of return holes on the pool which was really...
  2. M

    WhisperFlo VS and intelliconnect

    Will work on the plumbing tomorrow weather permitting. What do you mean by a deep cleaning? I do backwash once I see the pressure in the filter rise.
  3. M

    WhisperFlo VS and intelliconnect

    I have to run at 2500 to engage the flow switch, which is why I am wanting to mix that with some low rpm run time. I am about to redo the plumbing though, because the pool builder (previous owner of my house installed the pool) installed the IC40 vertically and upside down. I will look into...
  4. M

    WhisperFlo VS and intelliconnect

    Ok, for some reason I thought it would attempt to produce if the percentage lights are on with low flow. So is it safe to have the pump running at a speed that doesn’t provide enough flow to IC40? I will have a program set at a high enough speed to make sure I get enough chlorine output, but...
  5. M

    WhisperFlo VS and intelliconnect

    I was able to fix this. For some reason it was resetting to 2550 in the pump controller even though I brought it to 0 during the setup. While running I bumped it down to 0 on the pump itself and then it started running the speeds correctly from the Pentair Home App. However it seems I have...
  6. M

    WhisperFlo VS and intelliconnect

    I finally was able to hook up my heater and IC40 and now the pump will run at 2550 rpm no matter what the settings are. I have tried scheduled and manual programs and it will still just run at 2550. Any ideas?
  7. M

    WhisperFlo VS and intelliconnect

    There are 4 programs available, I just only set up two of them until I get everything else connected to the IntellicConnect and figure out exactly how I want it to run.
  8. M

    Will superflo vs connect to intelliconnect

    It works! You can see I was able to connect a WhisperFlo to IntelliConnect via RS485 today: WhisperFlo VS and intelliconnect
  9. M

    WhisperFlo VS and intelliconnect

    Finally had a break in the rain and we have success! The WhisperFlo VST pulled up as a Pentair VS (RS485) in the Pentair Home App. Followed the instructions in the page I attached in an earlier post to set speed to 0 for 24 hours and I was able to setup two programs and it is running as...
  10. M

    WhisperFlo VS and intelliconnect

    Promising. Of course it’s raining.
  11. M

    WhisperFlo VS and intelliconnect

    I just installed a WhisperFlo VST to replace an older single speed Whisperflo. After realizing the inability to have the pump running with the IC40 off, I ordered the IntelliConnect and RS-485 (356324Z). They should arrive today, so once the weather clears up I will install and report back...