Recent content by briggss3

  1. B

    Side suction and bottom drain problems....I give up.

    My quicklock looks ti be broken. It's not horrible but it's also not air tight. I am going to see if a 6 inch sewer plug will work.
  2. 1000017783.jpg

    1000017783.jpg

  3. B

    Side suction and bottom drain problems....I give up.

    Yes I have the infloor cleaning system. Here are the pics I took at my pump pad Suction on the 3 way Jandy. Discharge through the A&A manifold.
  4. 1000017312.jpg

    1000017312.jpg

  5. 1000017306.jpg

    1000017306.jpg

  6. B

    Side suction and bottom drain problems....I give up.

    I was surprised he said what he said. I went back online and saw they had issues a few years agai and redesigned the plates. I love mine so far. Bahhh humbug
  7. B

    Side suction and bottom drain problems....I give up.

    Ok. Had a local builder with 40 years experience out. He said this is a very rare contraption to see nowadays and he thinks it's made by A&A. They spent 30 to 45 minutes screwing with it and could also NOT get the device to stop overdrawing water and pulling air in. It's a bad design and is...
  8. B

    Side suction and bottom drain problems....I give up.

    Thanks Jim. Just talked to a local shop here and he has seen them before but has no idea how they operate. Water just seems to flow through and does not fill up like the suction bowl does on the pump. The little plunger lid that fits on top is not secure and pops off easy. I have a builder...
  9. B

    Side suction and bottom drain problems....I give up.

    Anyone have any advice on this? I guess I can run a fish tape through the lines to confirm if there is a block in the line. The skimmer sock seems like it would have stopped anything from plugging the line though.
  10. B

    Side suction and bottom drain problems....I give up.

    Yep. Pump simply will not run on the bottom or vacuum port suction side. Gets about a gulp of water then goes dry. I suppose I could fishtail it back to see if something is in the line but I doubt it. Strainer sock was in tact and about 1/2 full of small debris. Hopefully someone has some...
  11. B

    Side suction and bottom drain problems....I give up.

    What is this contraption and is it why my suction cleaner (polaris maxx) won't operate? No matter the position on the jandy valve, there is little to no suction produced on the side port. This in ground clean out system has water flowing through it as you can see but it's certaiy not sealed to...
  12. 1000017731.jpg

    1000017731.jpg

  13. 1000017724.jpg

    1000017724.jpg

  14. 1000017732.jpg

    1000017732.jpg

  15. B

    RJ 60 No Salt and No Light

    I will look for the pump and add that. INTERTEC timer and the pu.p.is wired to the timer switch with the pump. I am using the TF100 Pro Salt kit and my results are: FC - 7 TO 8 FAS DPD CC - 0 to 0.5 pH - 7.5 to 7.7 but dropping daily to 7 for TA TA - 200 dropped from 260 on to 70 CH - 250 up...